  1.                    THENET X1-J4 QUICK REFERENCE GUIDE
  2. ==================================================================
  3.                            SWITCH COMMANDS
  4.  
  5. ACL       [{CALLSIGN + VALUE} | {CALLSIGN - VALUE} |
  6.            { * VALUE } | { & value }]
  7. ADC
  8. ADC1      [ * | Units_for_Voltmeter_channel_1 ] (see note 6)
  9. ADC2      [ * | Units_for_voltmeter_channel_2 ] (see note 6)
  10. ADC3      [ * | Units_for_Voltmeter_channel_3 ] (see note 6)
  11. ADC4      [ * | Units_for_voltmeter_channel_4 ] (see note 6)
  12. ALIAS     [ * | NEW_ALIAS ]
  13. ARP       [ipaddr [{ - ptcl } | [+ [P] ptcl callsign [DG | VC ]]]
  14. ARPTIMER  [ * | enable_flag [ * | timer_rate ] ]
  15. AUDIT     [ NUMBER_FROM_0_TO_255 ]
  16. BBS       [ CALLSIGN | * | ? ]
  17. BBSALIAS  [ * | NEW_ALIAS ]
  18. BRATE     [ * | radio_brate [ * | rs232_baud_rate ]] (PK96 only )
  19. BTEXT     [ * | BEACON_MESSAGE_TEXT ] (see note 6)
  20. BYE
  21. CALIBRATE [PERIOD_VALUE_FROM_1_TO_60 [TOGGLE_VALUE_1_TO_PERIOD ] ]
  22. CLOSEDOWN A
  23. CONNECT   [ CALLSIGN [ [V] DIGILIST ... ]
  24. CQ        [ MESSAGE_FOR_CQ_PACKET ]
  25. CTEXT     [ * | CONNECT_MESSAGE_TEXT ] (see note 6)
  26. DXCLUSTER [ CALLSIGN | * | ? ]
  27. DXCALIAS  [ * | NEW_ALIAS ]
  28. HELP
  29. HOST      [ CALLSIGN | * | ? ]
  30. HOSTALIAS [ * | NEW_ALIAS ]
  31. INFO      [ SYSOP_SET_MESSAGE ] (see note 6)
  32. IPADDRESS [ NEW_IP_ADDRESS ]
  33. IPBROADCAST [ NEW_IP_ADDRESS ]
  34. IPROUTE   [ipaddr [/bits ] [ - | { + port [ipgateway[metric ]]]]
  35. IPSTATS   [ { NEWPARAM | * } { NEWPARAM | * } ..... ] (see note 5)
  36. L3MHEARD  [ NUMBER_FROM_1_TO_100 ]
  37. LINKS
  38. MANAGER
  39. METER     [ { new_value | * } ... ] (see note 5)
  40. MHEARD    [ NUMBER_FROM_1_TO_100 ]
  41. MODE      [ { NEWPARAM | * } { NEWPARAM | * } ..... ] (see note 5)
  42. MTU       [ list_of_parameters ] (see note 5)
  43. NODES     [* [*] | NODECALL {+|-} IDENT QUAL COUNT PORT NEIGHBOUR
  44.           [DIGIS]]
  45. PARMS     [ { NEWPARAM | * } { NEWPARAM | * } ..... ] (see note 5)
  46. QUIT
  47. RESET     [ ANY_CHARACTER ]
  48. ROUTES    [ PORT NODECALL [ DIGILIST ... ] { + | - } PATHQUALITY ]
  49. STATS
  50. SYSOP
  51. TALK      [ STRING ]
  52. UI        DEST   STRING_OF_TEXT_TO_BE_SENT_IN_UI_FRAME
  53. USERS
  54. ------------------------------------------------------------------
  55.  
  56. Note 1 Any command may be enabled or disabled by the
  57.        use of the '+' or '-' modifier, as shown below :
  58.  
  59.           ANY_COMMAND   [ + | - | THAT_COMMANDS_PARAMETERS ]
  60.  
  61.        Commands may be caused to be displayed or not in
  62.        the prompt screen if the '-' or '+' is followed
  63.        by 'D' ( or 'd' )
  64.  
  65. Note 2 IP addresses are of the form nnn.nnn.nnn.nnn
  66.        where nnn is a number 0..255
  67.  
  68. Note 3 IProute port parameter is 0 for radio or 1 for
  69.        rs232
  70.  
  71. Note 4 ARP ptcl parameter is AX.25 or Net/Rom (may be
  72.        abbreviated)
  73.  
  74. Note 5 The commands will accept the 'old' syntax of '*
  75.        * * value...' or the new offset & value syntax of
  76.        '/ parameter_number value'
  77.  
  78. Note 6 Voltmeter channels 1,2,3,4 correspond to ADC channels 3,4,1,2 
  79.        respectively. The ADC command reads them.
  80.  
  81.  
  82.                         HOST 'ESCAPE' COMMANDS
  83.  
  84. <escape> C
  85. <escape> D
  86. <escape> P  [ NEW_PASSWORD ]
  87.  
  88. ==================================================================
  89.  
  90. UNDERSTANDING ACL VALUES              UNDERSTANDING AUDIT BITS
  91. ------------------------------------------------------------------
  92. Bit   Function                   | Bit    Function
  93. =================================|================================
  94.  0  Bar all incoming L2 connects |  0 Issue L1 stats every 10 mins
  95.  1  Bar outgoing L2 downlinks    |  1 Audit L2 connects & discs
  96.  2  Ignore nodes broadcasts      |  2 unused
  97.  3  Bar gatewaying at level 3    |  3 Audit L4 connects & discs
  98.  4  Bar incoming L4 connects     |  4 Audit L7 use of sysop cmd
  99.  5  Bar outgoing L4 connects     |  5 Audit all L7 switch commands
  100.  6  ignore SSID in searching     |  6 Issue CPU stats every 10mins
  101.  7  unused                       |  7 unused
  102.  
  103. ==================================================================
  104.  
  105.                         PARMS PARAMETERS
  106.  
  107. Number Min    Max  Function
  108. -----------------------------------------------------------
  109.   1      1    400  Maximum number of destination nodes
  110.   2      0    255  Minimum quality for auto update
  111.   3      0    255  HDLC ( radio, port 0 ) default quality
  112.   4      0    255  RS232 ( crosslink, port 1 ) default quality
  113.   5      0    255  Initial value for obsolescence counter
  114.   6      1    255  Minimum obsolescence for node broadcast
  115.   7      0  65535  Auto update broadcast interval (seconds)
  116.   8      0    255  Level 3 ( network ) Time To Live Initialiser
  117.   9      5    600  Level 4 ( transport ) timeout (seconds)
  118.  10      1    127  Level 4 ( transport ) retries
  119.  11      1     60  Level 4 ( transport ) ack delay (seconds)
  120.  12      1   1000  Level 4 ( transport ) busy delay (seconds)
  121.  13      1    127  Level 4 ( transport ) window size (frames)
  122.  14      1    127  Level 4 ( transport ) congestion ctrl threshold
  123.  15      0  65535  Level 7 ( switch ) inactivity timeout (seconds)
  124.  16      0    255  Persistance for transmit delay
  125.  17      0    127  Persistance slottime delay (10's of msecs)
  126.  18      1     15  Level 2 ( link ) T1 timeout, ie FRACK (seconds)
  127.  19      1      7  Level 2 ( link ) window size (packets)
  128.  20      0    127  Level 2 ( link ) retries
  129.  21      0   6000  Level 2 ( link ) T2 timeout (10's of msecs)
  130.  22      0  65535  Level 2 ( link ) T3 timeout (10's of msecs)
  131.  23      0      1  Level 2 ( link ) digipeat enable flag
  132.  24      0      1  Callsign validation flag
  133.  25      0      2  Node beacon ctrl (0=off, 1=if active, 2=always)
  134.  26      0      1  CQ broadcasts enable flag
  135.  
  136. ==================================================================
  137.                         MODE PARAMETERS
  138. Number Min    Max  Function
  139. -----------------------------------------------------------
  140.   1      0      1  Hardware handshake host control mode flag
  141.   2      0   3600  CWID repeat period ( seconds )
  142.   3      4     10  CWID speed ( 10's msecs per dot )
  143.   4      0      3  Nodes broadcast channel enable flags where
  144.                    0=none, 1=HDLC only, 2=RS232 only, 3=Both ports
  145.   5      0      3  Crosslink protocol selection
  146.                    0=crosslink, 1=KISS,
  147.                    2=KISS+selective copy, 3=KISS+allcopy
  148.   6      0    255  TX keyup delay ( 10's of milliseconds )
  149.   7      0      1  Full duplex enable flag
  150.   8      0  65535  RS232 ( port 1 ) node broadcast period ( secs )
  151.   9      0      3  Node broadcast algorithm control flags
  152.                    0=off, 2=RS232 port, 1 & 3 not normally used
  153.  10    600   3600  Beacon interval ( seconds )
  154.  11      0      2  Connect redirection to BBS flag
  155.  12      0    255  Help messages flags, 8 bit TALK, case & TEXNET
  156.  13      0      3  Hash node broadcast disable (one bit per port)
  157.  14      0      1  Enable extra aliases monitoring if set
  158.  15      0      1  Enable auto reconnect to node after remote dis
  159.  16      0      3  Slime trail control. Each bit controls...
  160.                    Bit 0 if set hides slime trails in nodes list
  161.                    Bit 1 if set causes slime trails to be ignored
  162.  17      0      3  Digipeat control. Each bit controls ...
  163.                    Bit 0 set makes node to refuse digi'd L2 uplink
  164.                    Bit 1 set, node refuses to allow digi downlinks
  165. ==================================================================
  166.                         IPSTAT PARAMETERS
  167. Number Min    Max  Function  ( Those marked '*' are not used )
  168. -----------------------------------------------------------
  169.   1      0      3  ip L2 AX.25 Modes ( 1 bit per port, 1=DG )
  170.   2      0      1  ip Forwarding, 1=enable router, 0=disable
  171.   3      2    255  ip Default TTL
  172.   4      0      0  ip In Receives
  173.   5      0      0  ip In Header Errors
  174.   6 *    0      0  ip In Address Errors
  175.   7      0      0  ip Forwarded Datagrams
  176.   8      0      0  ip In Unknown Protocols
  177.   9 *    0      0  ip In Discards ( TTL exceeded )
  178.  10 *    0      0  ip In Delivers
  179.  11      0      0  ip Output Requests
  180.  12 *    0      0  ip Output Discards
  181.  13      0      0  ip Output No Routes
  182.  14 *    1     30  ip Reasm Timeout
  183.  15 *    0      0  ip Reasm Requireds
  184.  16 *    0      0  ip Reasm OKs
  185.  17 *    0      0  ip Reasm Fails
  186.  18      0      0  ip Frag OKs
  187.  19 *    0      0  ip Frag Fails
  188.  20      0      0  ip Frag Creates
  189. =================================================================
  190.  
  191.                     MTU PARAMETERS
  192. Number Min    Max  Function
  193. -----------------------------------------------------------
  194.  1      64   1024  IP Port 0 ( Radio Port ) Level 2 AX.25 MTU
  195.  2      64   1024  IP Port 1 ( RS232 Port ) Level 2 AX.25 MTU
  196.  3      64    236  IP Net/Rom port MTU
  197.  4     257   1025  Level 2 Max data bytes in a packet before error
  198.  5     328   1096  Level 2 Total max packet size in bytes
  199.  
  200. =================================================================
  201.  
  202.                    METER PARAMETERS
  203. Number Min    Max  Function
  204. -----------------------------------------------------------
  205.  1       0    511  The meter mode flags
  206.  2       0    255  The deviation meter scaling factor
  207.  3       0    255  The signal strength meter noise floor value
  208.  4       0    255  The S meter display format multiplier
  209.  5       0    255  The dBm meter display format multiplier
  210.  6       0    255  The dBm noise floor value
  211.  7       0    255  The voltmeter channel 1 multiplier
  212.  8       0    255  The voltmeter channel 2 multiplier
  213.  9       0    255  Voltmeter Channel 1 offset value
  214. 10       0    255  Voltmeter Channel 2 offset value
  215. 11       0    255  The voltmeter channel 3 multiplier 
  216. 12       0    255  The voltmeter channel 4 multiplier
  217. 13       0    255  Voltmeter Channel 3 offset value
  218. 14       0    255  Voltmeter Channel 4 offset value
  219.  
  220.  
  221. ==================================================================
  222.  
  223.       THE METER MODE FLAGS ( METER parameter 1 )
  224.  
  225. BIT       If set, then ....
  226. -----------------------------------------------------------
  227.  0        The deviation meter is enabled
  228.  1        The signal strength meter is enabled
  229.  2        The signal strength is shown as S points rather than dBm
  230.  3        ADC channel 3 is enabled ( voltmeter channel 1 )
  231.  4        ADC channel 4 is enabled ( voltmeter channel 2 )
  232.  5        Voltmeter channel 1 divisor is 1000 rather than 100
  233.  6        Voltmeter channel 2 divisor is 1000 rather than 100
  234.  7        Voltmeter channel 1 display resolution is 0.1 not 1.0
  235.  8        Voltmeter channel 2 display resolution is 0.1 not 1.0
  236.  9        ADC channel 1 is enabled ( voltmeter channel 3 )
  237. 10        ADC channel 2 is enabled ( voltmeter channel 4 )
  238. 11        Voltmeter channel 3 divisor is 1000 rather than 100
  239. 12        Voltmeter channel 4 divisor is 1000 rather than 100
  240. 13        Voltmeter channel 3 display resolution is 0.1 not 1.0
  241. 14        Voltmeter channel 4 display resolution is 0.1 not 1.0
  242.  
  243. ==================================================================
  244.  
  245.        HELP MESSAGES FLAGS ( MODE Parameter 12 )
  246.  
  247. BIT       FUNCTION
  248. -----------------------------------------------------------
  249. 0         If set, the 'please wait, trying xxxx' operates
  250. 1         If set, all commands appear in help for sysop
  251. 2         If set, the 'goodbye' message is given
  252. 3         If set, a welcome message is enabled ( CTEXT )
  253. 4         If set, nodes are shown as 'alias:callsign'
  254. 5         If set, TALK data is passed as 8 bit data
  255. 6         If set, node aliases are deemed to be case sensitive
  256. 7         If set, enables the TexNet "*** LINKED to" interface
  257.  
  258. =================================================================
  259.  
  260.                   ARPTIMER PARAMETERS
  261. Number Min    Max  Function
  262. -----------------------------------------------------------